Mfg Part Number: 874-0012 | Alternate P/N: 8740012 | Manufacturer: Northern Telecom Systems Corp |
NSN : 5945-00-557-2913 | Item Name : relay electromagnet | CAGE Code : 62143 |
FSC : 5945 Relays and Solenoids |
Thank you for your interest in NSN Part 874-0012 of Relay Electromagnet at Automatic Aerospace. This Northern Telecom Systems Corp manufacturer item is listed alongside with NSN 5945-00-557-2913 and part 874-0012 for your reference. As this product is currently available, we encourage you to take advantage of our Instant RFQ service in order to acquire a competitive quote for your comparisons. With 24/7x365 team member availability, responses to requests or inquiries are completed with haste.
Explore our listings at your leisure and you will find that the part 874-0012 of NSN 5945-00-557-2913 can be found listed under CAGE Code 62143. However, we carry an array of other NSN parts, all of which have been sourced from reputable distributors like Northern Telecom Systems Corp. Kickoff the purchasing process with a quote request that includes all of your part requirements and see how Automatic Aerospace can serve as your go-to sourcing solution. For additional questions, call or email us directly; we are on standby for our customers.
NSN | FSC | NIIN | CLS | Hazmat | DEMIL | Cancelled NSN |
---|---|---|---|---|---|---|
5945-00-557-2913 Item Description: Relay Electromagnet | 5945 | 005572913 | 0 | N | ||
CIIC | HCC | ESD | PMIC | Criticality | ENAC | |
U | U | |||||
Part Number | ISC | RNVC | RNCC | HCC | MSDS | SADC |
874-0012 | 6 | 9 | 5 |
MRC | Criteria | Characteristic |
---|---|---|
ABHP | OVERALL LENGTH | 3.620 INCHES NOMINAL |
ABKQ | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO LENGTH | 3.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKR | CENTER TO CENTER DISTANCE BETWEEN MOUNTING FACILITIES PARALLEL TO WIDTH | 1.000 INCHES NOMINAL SINGLE MOUNTING FACILITY |
ABKW | OVERALL HEIGHT | 3.250 INCHES NOMINAL |
ABMK | OVERALL WIDTH | 1.750 INCHES NOMINAL |
ADZC | ENVIRONMENTAL PROTECTION | HERMETIC |
AEBV | UNTHREADED MOUNTING HOLE DIAMETER | 0.205 INCHES NOMINAL SINGLE MOUNTING FACILITY |
AKDX | WINDING QUANTITY | 1 |
APCN | COIL QUANTITY | 1 |
APNA | WINDING DC RESISTANCE RATING | 200.0 OHMS NOMINAL SINGLE WINDING |
APNP | DUTY TYPE | CONTINUOUS |
AXHR | MOUNTING FACILITY TYPE AND QUANTITY | 4 UNTHREADED HOLE SINGLE MOUNTING FACILITY |
CQYJ | MOUNTING FACILITY PATTERN | RECTANGULAR SINGLE MOUNTING FACILITY |
CRNG | NONPILE-UP MAIN CONTACT ARRANGEMENT | 1 TWO CIRCUIT, BOTH POSITIONS MAINTAINED |
CRPQ | NOMINAL OPERATING CURRENT RATING AND TYPE | 500.0 MILLIAMPERES DC SINGLE WINDING |
CSXF | OPERATING VOLTAGE RATING AND TYPE AT SPECIFIED TEMP | 26.5 VOLTS DC 25 DEG CELSIUS SINGLE WINDING |
CTDL | MAIN CONTACT LOAD CURRENT RATING AT MAXIMUM RATED VOLTAGE | 50.0 AMPERES AC RESISTIVE LOAD AND 50.0 AMPERES DC RESISTIVE LOAD |
CWAB | MAIN CONTACT MAXIMUM VOLTAGE RATING IN VOLTS | 115.0 AC AND 28.0 DC |
TTQY | TERMINAL TYPE AND QUANTITY | 6 PIN ALL FUNCTIONS |
![]() |
“We Proudly Support Intrepid Fallen Heroes Fund that serves United States Military Personal experiencing the Invisible Wounds of War : Traumatic Brain Injury (TBI) and Post Traumatic Stress (PTS). Please visit website (www.fallenheroesfund.org) and help in their valiant effort”. |
We Hope that You Will Visit Us Again the Next Time You Need NSN Parts and Make Us Your Strategic Purchasing Partner.